Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…

1999

Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…

AdultMalemedicine.medical_specialtyDefibrillationTest groupmedicine.medical_treatmentImplantable defibrillatorDefibrillation thresholdElectrocardiographyLow energyInternal medicineMedicineHumansProspective StudiesAgedEjection fractionEquipment Safetybusiness.industryMiddle AgedImplantable cardioverter-defibrillatorDefibrillators ImplantableSurvival RateTreatment OutcomeShock (circulatory)Ventricular FibrillationCardiologyTachycardia VentricularFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessSoftwareThe American journal of cardiology
researchProduct

[Is ICD-programming for double intraoperative defibrillation threshold energy safe and effective during long-time follow-up? Results of a prospective…

1999

The aim of this prospective and randomized study was to evaluate the safety and efficacy of a reduced shock strength in transvenous implantable defibrillator therapy. So far clinical data concerning the safety margin of the shock energy in ICD therapy do not exist. The shock energy tested during long-term follow-up in this study was twice the intraoperatively measured defibrillation threshold (DFT). A total number of 176 consecutive patients representing a typical cohort of ICD patients were evaluated. All patients received a non-thoracotomy lead system (CPI, Endotak 0070, 0090) and a biphasic cardioverter-defibrillator with the ability to store episodes (Cardiac Pacemakers Inc., Ventac TM …

inorganic chemicalsMalemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentElectric CountershockImplantable defibrillatorAmiodaroneSudden cardiac deathlaw.inventionDefibrillation thresholdIntraoperative PeriodRandomized controlled triallawInternal medicinemedicineHumansProspective StudiesEquipment Safetybusiness.industryMiddle Agedmedicine.diseaseSurgeryDefibrillators ImplantableShock (circulatory)Ventricular fibrillationCardiologymedicine.symptomCardiology and Cardiovascular Medicinebusinessmedicine.drugFollow-Up StudiesZeitschrift fur Kardiologie
researchProduct

Experimental study on the effects of physical training on the defibrillation threshold

2011

Background: Chest compression artifacts during cardiopulmonary resuscitation (CPR) deteriorate the rhythm diagnosis of automated external defibrillators (AED). Cardiopulmonary resuscitation must therefore be interrupted for a reliable shock/no-shock decision. However, these hands-off intervals adversely affect the defibrillation success, and, in addition, pauses in chest compressions compromise circulation. An accurate diagnosis of the rhythmwhile performing CPR is therefore needed to minimize these hands-off intervals. Methods: The characteristics of the CPR artifact are very variable, and the artifact presents an important spectral overlap with human cardiac arrest rhythms. Consequently, …

medicine.medical_specialtyArtifact (error)Compression artifactDefibrillationbusiness.industrymedicine.medical_treatmentmedicine.diseaseAdaptive filterDefibrillation thresholdInternal medicineVentricular fibrillationmedicineCardiologyCardiopulmonary resuscitationAsystoleCardiology and Cardiovascular MedicinebusinessJournal of Electrocardiology